Surgical face mask 6002-2 EO sterilized

Model: 6002-2 EO sterilized

The 6002-2 anti-particle mask is a disposable protective mask that is lightweight and provides users with reliable respiratory protection. At the same time, it meets the user’s need for mask protection and comfort performance.

• BFE ≥ 98%
• Headband Mask
• Fold ing type
• No exhaust valve
• No activated carbon
• Color: White
• Latex free
• Fiberglass free
• EO sterilized


Product Detail

Information

ADDITIONAL INFORMATION

Materials
• Surface: 60g non woven fabric
• Second layer: 45g hot air cotton
• Third layer:50g FFP2 filter material
• Inner layer: 30g PP non woven fabric

Approvals and Standards
• EU Standard: EN14683:2019 Type IIR
• EU Standard: EN149:2001 FFP2 Level
• License for the manufacturing of industrial products

Validity
• 2 years

Use for
• Used to protect against particulate matter generated during processing such as grinding, sanding, cleaning, sawing, bagging, or processing of ore, coal, iron ore, flour, metal, wood, pollen, and certain other materials.

Storage Condition
• Humidity<80%, well-ventilated and clean indoor environment without corrosive gas

Country of Origin
• Made in China

Description

Box

Carton

Gross weight

Carton size

Surgical face mask 6002-2 EO sterilized  20pcs  400pcs  9kg/Carton  62x37 x38cm

  • Previous:
  • Next:

  • This product complies with the requirements of EU Regulation (EU) 2016/425 for Personal Protective Equipment and meets the requirements of European standard EN 149:2001+A1:2009. At the same time, it complies with the requirements of EU Regulation (EU) MDD 93/42/EEC on medical devices and meets the requirements of European Standard EN 14683-2019+AC:2019.

    User instructions
    The mask must be selected properly for intended application. An individual risk assessment must be evaluated. Check the respirator that is undamaged with no visible defects. Check the expiry date that has not been reached (see the packaging). Check the protection class that is appropriate for the product used and its concentration. Do not use the mask if a defect is present or the expiry date has been exceeded. Failure to follow all instructions and limitations could seriously reduce the effectiveness of this particle filtering half mask and could lead to illness, injury or death. A properly selected respirator is essential, before occupational use, the wearer must be trained by the employer in the correct use of the respirator in accordance with applicable safety and health standards.

    Intended use
    This product is limited to surgical operations and other medical environment where infectious agents are transmitted from staff to patients. The barrier should also be effective in reducing oral and nostril discharge of infectious substances from asymptomatic carriers or clinically symptomatic patients and in protecting against solid and liquid aerosols in other environments.

    Using method
    1. Hold the mask in hand with the nose clip up. Allow head harness to hang freely.
    2. Position the mask under the chin covering mouth and nose.
    3. Pull the head harness over the head and position behind head, adjust the length of head harness with adjustable buckle to feel as comfortable as possible.
    4. Press soft nose clip to conform snugly around the nose.
    5. To check fit, cup both hands over the mask and exhale vigorously. If air flows around nose, tighten the nose clip. If air leaks around the edge, reposition the head harness for better fit. Re-check the seal and repeat the procedure until the mask is sealed properly.

    product

    Background
    Medical devices are sterilized in a variety of ways including using moist heat (steam), dry heat, radiation, ethylene oxide gas, vaporized hydrogen peroxide, and other sterilization methods (for example, chlorine dioxide gas, vaporized peracetic acid, and nitrogen dioxide).

    Disinfection is the antimicrobial reduction of the number of viable microorganisms to a level previously specified as appropriate for its intended further handling or use. Sterilization is a defined process used to render a surface or product free from viable organisms, including bacterial spores. It also frequently includes the objective of allowing the maintenance of the sterile state

    Reasons to use Ethylene Oxide (EO)
    Medical devices are sterilized in a variety of ways including using moist heat (steam), dry heat, radiation, ethylene oxide gas, vaporized hydrogen peroxide, and other sterilization methods (for example, chlorine dioxide gas, vaporized peracetic acid, and nitrogen dioxide). Ethylene oxide sterilization is an important sterilization method that manufacturers widely use to keep medical devices safe.
    Ethylene oxide is a flammable, colorless gas used to make other chemicals that are employed in making a range of products, including textiles, plastics, detergents and adhesives. Ethylene oxide also is used to sterilize equipment and plastic devices that cannot be sterilized by steam, gamma and other sterilants such as medical devices.

    Sterility Test was tested on the product
    The population of viable microorganisms present on or in product was tested according to ISO 11737-2: 2009.
    Take 10 samples in the package, and inoculate each sample into 100 mL Fluid Thioglycollate Medium (FTM) and 100 mL Trypticase Soy Broth (TSB) after aseptic cutting. The FTM is placed in an incubator at 35°C, and TSB is placed in an incubator at 25°C for 14 days. Add 80cfu Staphylococcus aureus to the culture medium and cultured in the incubator for 5 days as a positive control. For the negative control, 100 mL FTM and 100 mL TSB are cultured in incubators for 14 days. Observe the growth of microorganisms every day.
    The results showed that no releases affecting the growth of microorganisms were detected in the test samples. The test article met the criteria, and the test results are valid.
    Based on the above results, it can be concluded that under the experimental conditions, the test samples are sterile.